Description
Features
Parallel Operation: Up to six MultiPlus units can operate in parallel for higher power output. Three units can be configured for three-phase output.
PowerControl: Efficiently manages limited generator, shore side, or grid power.
PowerAssist: Boosts the capacity of shore or generator power by adding inverter power when needed.
Four Stage Adaptive Charger: Fine-tunes the three-stage automatic process to suit the battery’s condition and adds a fourth stage for extended float charging.
High Start-up Power: Suitable for high inrush loads such as power converters for LED lamps, halogen lamps, or electric tools.
Search Mode: Reduces the inverter’s power consumption in no-load operation by approximately 70%.
Programmable Relay: Set by default as an alarm relay, it de-energizes in the event of an alarm or pre-alarm.
Remote On/Off: Allows for remote operation.
Specifications
Inverter:
Input voltage range: 19 – 33 V
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0.1%
Continuous output power at 25°C: 2000 VA / 1600 W
Continuous output power at 40°C: 1400 W
Peak power: 3500 W
Maximum efficiency: 93 / 94 / 95%
Zero load power: 10 / 9 / 10 W
Zero load power in search mode: 3/3/3W
Charger:
Input voltage range: 187-265 VAC
Charge voltage ‘absorption’: 28.8 V
Charge voltage ‘float’: 27.6 V
Storage mode: 26.4 V
Charge current: 50 A
General:
Operating temperature range: -40 to +65°C (fan assisted cooling)
Humidity: max 95% (non-condensing)
Weight: 10.2 kg
Dimensions (HxWxD): 470 x 265 x 120 mm