Specifications
Continuous power at 25°C: 1000W (for the 12/1200 model)
Peak power: 2200W
Output AC voltage/frequency: 230VAC or 120VAC +/- 3%, 50Hz or 60Hz +/- 0.1%
Input voltage range: 9.2 – 17V
DC low shut down (adjustable): 9.3V
Dynamic cut-off: Configurable
Battery charged detect: 14.0V
Max. efficiency: 91%
Zero-load power in ECO mode: 7W
Protection features: Output short circuit, overload, battery voltage too high/low, temperature too high, DC ripple too high.
Operating temperature range: -40 to +65°C (fan-assisted cooling)
Humidity: Max. 95% non-condensing
Material & Colour: Steel chassis and plastic cover (blue Ral 5012)
Battery connection: Screw terminals
Maximum cable cross-section: 35mm²
Weight: 7.4kg
Dimensions (HxWxD): 117 x 232 x 327 mm
Standard AC outlets: 230V: Schuko, IEC-320, UK, AU/NZ
Protection category: IP 21